Voltage Control Commands
Copyright ©ITECH Electronic Co., Ltd. 29
Chapter8 Voltage Control Commands
VOLTage
{<volts>|MINimum|MAXimum|UP|DOWN|DEF}
This order is used to set the output voltage. No matter what the voltage range
you select currently, the output voltage is subject to the newest setting value.
Besides, MIN and MAX can be used as parameters.MIN represents 0V,MAX
represents the max value of the voltage range. You may send VOLT? MIN or
VOLT? MAX orders to quire the minimum and maximum voltage within the
range. DEF represents default value, it also can be used to set value.
We can also send VOLT UP and VOLT DOWN orders to increase or decrease
voltage, the stepping value should be set with order ” VOLTage:STEP”. If
adjusted value has exceeded the voltage range, then error information will be
return:error-222.
Order syntax:
[SOUR:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf>
Parameters:
MIN to MAX
Unit:
V
*RST value:
MIN
Query syntax:
VOLTage? [MINimum|MAXimum]
Return parameters:
<NR2>
Example:
VOLT:STEP 0.01 //set the stepping value to be 0.01V
VOLT UP //enable the output voltage increase one time
VOLT:STEP 0.02 //set the stepping value to be0.02V
VOLT DOWN //enable the output value decrease one time
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT6932A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6932A and is the answer not in the manual?

ITech IT6932A Specifications

General IconGeneral
BrandITech
ModelIT6932A
CategoryPower Supply
LanguageEnglish

Related product manuals