Input Settings
Copyright © ITECH Electronic Co., Ltd. 27
Parameters
MIN~MAX | MAXimum | MINimum
Unit
A/uS
*RST Value
MAXimum
Examples
CURR:SLEW RISE 3
Query Syntax
[SOURce:]CURRent:SLEW:RISE?
Returned Parameters
<NR2
[SOURce:]CURRent:SLEW:RISE?
This command is used to query the slew rate of the current for positive going
transitions.
Command Syntax
[SOURce:]CURRent:SLEW:RISE?
Unit
A/uS
*RST Value
MAXimum
[SOURce:]CURRent:SLEW:FALL <NRf+>
This command sets the slew rate of the current for negative going transitions.
Command Syntax
[SOURce:]CURRent:SLEW:FALL <NRf+>
Parameters
MIN~MAX | MAXimum | MINimum
Unit
A/uS
*RST Value
MAXimum