EasyManua.ls Logo

ITech IT8516C+ - Measurement of Voltage Rise Time; Saving and Recalling Settings

ITech IT8516C+
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input Settings
Copyright © ITECH Electronic Co., Ltd. 39
*RST Value
MIN
Examples
DYN:LOW 1
Query Syntax
[SOURce:]DYNamic:LOW[:LEVel]?
Returned Parameters
<NR2>
[SOURce:]DYNamic:LOW[:LEVel]?
This command is used to query the low-level load current in dynamic mode.
Command Syntax
[SOURce:]DYNamic:LOW[:LEVel]?
Parameters
None
Unit
A
*RST Value
0
[SOURce:]DYNamic:LOW:DWELl <NRf+>
This command is used to set the duration of low-level load current in dynamic
mode.
Command Syntax
[SOURce:]DYNamic:LOW:DWELl <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
S
*RST Value
MIN
Examples
DYN:LOW:DWEL 1

Table of Contents

Other manuals for ITech IT8516C+

Related product manuals