OCP Testing Commands
Copyright © ITECH Electronic Co., Ltd. 49
Examples
OCP:IST 3
Query Syntax
OCP:ISTart?
Returned Parameters
<NR2>
OCP:ISTart?
This command is used to query the start current of the OCP test.
Command Syntax
OCP:ISTart?
Parameters
None
Unit
A
OCP:IEND <NRf+>
This command is used to set the OCP cut-off current.
Command Syntax
OCP:IEND <NRf+>
Parameters
MIN~MAX
Unit
A
Examples
OCP:IEND 6
Query Syntax
OCP:IEND?
Returned Parameters
<NR2>
OCP:IEND?
This command is used to query the OCP cut-off current.