Measurement Commands
Copyright © Itech Electronic Co., Ltd. 11
MEASure:CURRent:MINPeak?
FETCh:CURRent:MINPeak?
This command is used to read the negative peak current of electronic load.
Command syntax:
MEASure[SCALar:]CURRent:MINPeak?
FETCh:[SCALar:]CURRent:MINPeak?
Returned value:
<NR3>
MEASure:CURRent:MAXPeak?
FETCh:CURRent:MAXPeak?
This command is used to read the positive peak current of electronic load.
Command syntax:
MEASure[:SCALar]:CURRent:MAXPeak?
FETCh[:SCALar]:CURRent:MAXPeak?
Returned value:
<NR3>
MEASure:FREQuency?
FETCh:FREQuency?
This command is used to read the frequency of Hertz as the unit.
Command syntax:
MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Returned value:
<NR3>