1.7 Glossary of ITOH DENKI terms
Term
Description
IB-P05 (IB)
iCEP
Ladder logic
Slave
Master
JOG operation
Direction
Zone
Upstream
Downstream
Tray
JAM timer
JAM error
Sensor timer
Sensor timer error
RUN hold timer
Sensor-ON delay timer
LD Recorder
A Profinet slave device made by Itoh Denki that supports input and output device for
motor run, sensor, etc.
ITOH DENKI’ s PC application for creating a ladder program and setting parameters.
iCEP stands for Itoh Configurator for Ethernet/IP and Profinet.
A program (ladder logic) to define the operation of each motor of IBs.
Program can be created by ITOH DENKI’ s PC application, “iCEP” .
Forcible run of a motor. Set with iCEP.
* The operation of ladder logic stops during JOG operation.
A timer that starts when the sensor of its own zone turns ON and stops when the
sensor turns OFF in a ZPA transfer. Detects transfer congestion in the zone.
An error indicating congestion in a zone. Occurs when JAM Timer turns on after a
specified period of time.
A timer that specifies the period of time for turning the motor continuously in its own
zone after the sensor of its own zone becomes OFF in a ZPA transfer
A timer to set the period of time for stopping delay after a tray reaches to own zone
(own sensor) in ZPA transfer.
ITOH DENKI’ s PC application to analyze a ladder program
Up to two ladder program logs can be recorded simultaneously.
A timer that starts when the upstream sensor changes from ON to OFF and stops when
the sensor of its own zone changes from OFF to ON in a ZPA transfer. Detects loss of
tray.
A device that operates under instructions from a master device
Indicates turing direction of a motor.
Indicates the transfer zone managed by a motor.
Indicates the upstream zone (carry-in zone).
Indicates the downstream zone (carry-out zone).
Indicates a product to be transferred on the conveyor.
An error indicating loss of tray. Occurs when Sensor Timer turns on after a specified
period of time.
A device that issues instructions to the slave devices
MDR
Motorized roller
Original notice - A1.2
16
Glossary of ITOH DENKI terms
IB-P05 Technical documentation
1. Introduction

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITOH DENKI IB-P05F-P and is the answer not in the manual?

ITOH DENKI IB-P05F-P Specifications

General IconGeneral
BrandITOH DENKI
ModelIB-P05F-P
CategoryController
LanguageEnglish

Related product manuals