17
DBO Data Format
Here the list data of data burst output via Optical probe:
Data output are:
01 Remaining Credit
02 Accumulated Energy
03 Voltage
04 Current
05 Power Instantaneous
06 Power Limit
07 Meter ID
08 Tariff Index
09 Trip Count due to over power
10 Power Failure count
11 Alarm Duration
12 Low Limit Alarm
13 KT-KRN
14 Tamper Status
15 Total Tamper
16 – 65 Event Log
66 – 115 50 credit token accepted
Example data:
_<1>Remain Credit:(001038.15*kWh)
<2> Cumulative Energy:(000005.84*kWh)
<3> Vrms:(000231.93*V)
<4> Irms:(000000.00*A)
<5> InsPower:(000000.00*kW)
<6> Power Limit:(000016.56*kW)
<7> ID :(000000000000)
<8> Tariff Index :(00000001)
<9> Trip Count Overload :(00000000)
<10> Power Off Count:(00000026)
<11> Alarm Duration:(00000010)
<12> Low Limit KWh :(00000020)
<13> KT - KRN :(2-2)
<14> Tamper status :(0)
<15> Total tamper :(00000016)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Earth tamper)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Reverse tamper)
<22/06/22 22:22><Bypass tamper)
<22/06/22 22:22><Reverse tamper)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Earth tamper)
<22/06/22 22:22><Earth tamper)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Bypass tamper)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Reverse tamper)
<22/06/22 22:22><Reverse tamper)
<22/06/22 22:22><Meter off)
<22/06/22 22:22><Meter off)