ITW Dynatec Programming Page 5-27
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Item Description
4
Use Temperature Integration
Depending on your Temp Module this function can be activated/ deactivated.
If you experience strong variations in actual temperature read-out, an integration function
can be activated to eliminate EMC influence.
5 These values are read-only.
6 Press the OK button to confirm your entered values and return to the previous screen.
7 Press the ESC button to discard any non-confirmed values and return to the previous screen.
8
Zone Status
Zone status is indicated.
ALM = is highlighted if zone has an alarm.
RTD = is highlighted if temperature sensor error occurs.
WT = is highlighted if zone is in wait status because of heating priority setting.
HT = is highlighted if zone is heating up.
RDY = is highlighted if zone ready (setpoint temperatures are reached).
Scale = Indication of Current Control Variable of the selected PID control zone.