Page 6-4 Maintenance
Revised 10/14
ITW Dynatec
D15/D25/D45 V6 D CL ASU Manual #20- 63
Pump Shaft Leak
There is a cutout in the base plate, directly below the pump
shaft, which will allow adhesive from a leaking pump to exit
the ASU. Inspect the area under the base plate cutout every
month for adhesive.
A leaking pump shaft indicates a worn pump seal. See
instructions in Chapter 8 for replacement of this seal.
Summary of Preventive Maintenance Schedule
Monthly (or as experience dictates)
Inspect output filter basket. Replace as required.
Check for leaking adhesive under the base plate, caused by a worn pump seal. Replace as required.
Every T hree Months (or as experience dictates)
Check all hose fittings for tightness.
Check all fasteners for tightness.
Inspect primary filter. Clean or replace as required.
Gear Pump
Seal Assembly