Page 5- 20 LCD Programming
Revised 10/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
change the function from activate or deactivate.
To program the controller to Stop the Pump After Hopper Empty, first press the Configuration
button ( ) or F1 to bring up the parameter, then press the Enter Knob to change the function
from activate or deactivate. To set the adjustable de lay, press the Enter Knob and then turn the
Input Wheel to select the desired length of the delay.
HeatUp Sequence (Priority) (P3)
The controller allows you to choose the heating order of the various temperature zones, so that
zones requiring more time to heat up to temperature can be programmed to begin heating be
fore others. This is done by programming each zone with a sequential heating priority.
A “Priority 1" designation means the temperature zone will begin to heat immediately after the
ASU is powered on. Zones with higher priority numbers (Priority 2 through Priority 6) do not
begin heating until all zones with lower priority values have reached the low limit of their set
points. Zones which are switched OFF are not applicable.
The most common heating sequence is first hopper, then hose/ head and auxiliary zones. This al
lows the larger mass of adhesive in the hopper to begin heating first. This sequence (hopper, then
hose/ heads and aux zones) is also the controller's default heating sequence.
After turning the Input Wheel to select the HeatUp Sequence parameter, press F1. On the
HeatUp Sequence screen, turn the Input Wheel to select a desired zone. Press the F4 button to
assign a priority number to the selected zone. Turn the Input Wheel to select another zone, if de
sired, and program its priority by pressing F4. Continue until all zones are programmed. Press the
Enter Knob to confirm, then press the RETURN button to return to the System Configuration
Menu.
Hose 1 (Z 4) has been
programmed as a Pri
ority 2 zone