ITW Dynatec
D SERIES V6 DCL ASU Manuals
Troubleshooting Page 7-9
Revised 10/14
V6
T
emperature
M
odule
PN
115735
The V6 TEMP module(s) is mounted next to t he V6 Base Module on the Din-rail. It requires
24VDC supply voltage. It is responsible for the temperature control of all heated temperature
zones. The RTD temperature sensors connect to this module and the TEMP module provides cor-
responding output signals to the power boards. Depending on the configuration of the ASU, the
RTDs may be PT100 (DynaControl) or NI120 (Nordson). Configuration is determined by a jumper
located within the module (see below, to left of module illustration).
Each of the maximum 15 zones has a status LED which shows its heating status in the following
manner:
- if the zone is switched off, the LED is Off,
- if the zone is heating, the LED is On,
- if the zone is near or at the setpoint temperature, the LED blinks.
Approx. location of the
jumper inside the module.
Dynacontrol RTD ASU: jump-
er positioned horizontally, as
above.
Nordson RTD ASU: jumper
positioned vertically, as above.
TO POWER
MODULE #3