Controller Setup Page 4-7
Revised 10/14
Settings for a Typical Operation
Note: The values given here are approximate settings for a typical packaging application. The val-
ues you choose will be based on the type of equipment and adhesive you are using and the nature of
your particular operation.
If Application Temperature is 177C (350F):
Hose and head temperature: 177C (350F).
Hopper setpoint temperature: 163C(325F).
Hi/ Lo limit deviation: 12C(20F).
ASU operating range: 149C to 177C (300Fto350F).
Standby condition temperature (deviation): 30C(50F).
Hopper over-temperature setpoint: 177C (350F)
Mechanical thermostat (for the hopper) over-temperature: 218C(425F)
For most operations, temperature fluctuations will be very small and of short duration. For these
reasons, the settings above are recommended.