Page 5-34 ITW Dynatec
Revised 1/16 V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
If Analog Level Sensor is installed:
Item Description
1
Parameter Selection tabs
The Level Control Settings tab has been selected.
2
Empty Level
If fill level is lower than this parameter an empty message will be generated.
3
Time Delay Empty Message
This is a programmable time delay for reappearance of the level control’s Empty message.
The level control device informs the operator via a "Minimum Level" message on the display
that the hopper needs to be refilled. After expiration of the time delay, the message
Minimum Level will be indicated on the display. The programmable range is 0-31 minutes.
Touch a zone input box and a numeric entry keypad will appear and the values can be
edited. Enter the value and confirm by pressing OK.
4
Warning Level (Min)
Template-dependent parameter (not used in standard configuration).
5
Switch Level (Start)
If system is configured as refiller control this parameter defines the refill start level.
6
Switch Level (Stop)
If system is configured as refiller control this parameter defines the refill stop level.
7
Alarm Level (Max)
Template-dependent parameter (not used in standard configuration).
8 Press the left-pointing arrow to go to the previous General Settings screen.
9 Press the right-pointing arrow to go to the next General Settings screen.
10 Press the OK button to confirm your entered values and return to the previous screen.
11 Press the ESC button to discard any non-confirmed values and return to the previous screen.
4
3
5
6
7
10
11
1
2
8
9