ITW Dynatec
D SERIES V6 DCL ASU Manuals
Troubleshooting Page 7-17
Revised 10/14
Temperature Sensor Resistance
(0.00385 PT 100 RTD)
Nominal Hopper Heater Resistance
Temperature Resistance
F CinOhms
32 0 100
50 10 104
68 20 108
86 30 112
104 40 116
122 50 119
140 60 123
158 70 127
176 80 131
194 90 135
212 100 139
230 110 142
248 120 146
268 130 150
284 140 154
302 150 157
320 160 161
338 170 164
356 180 168
374 190 172
392 200 176
410 210 180
428 220 183
Watts Resistance in Ohms
200 288
270 213
350 165
500 115
700 82
Nominal Head Heater Resistance
ASU Drop-in Grid
Qty. Heaters
21or2
Resistance in Ohms 22 ea.
for each heater:
200-240 v
19.4-24 ea.
380-400 v 57.8-66.7 ea.
Note: Resistance is measured at ambient temperature (20
C/ 68
F).
Hose Length Resistance
Meters Feet in Ohms
1.2 4 466-544
1.8 6 279-326
2.4 8 236-275
3 10 189-221
3.7 12 155-181
4.9 16 118-137
7.3 24 77-90
Nominal Hose Heater Resistance
for #6 DynaFlex Hoses