Page 5-14 ITW Dynatec
Revised 1/16 V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
Item Description
1 System 1 Pump 1 is selected.
2
Pump Name
Touch the input box and an Alphabetic Entry Keypad will appear. Enter your desired pump
name and confirm by pressing OK.
The entered pump name will be displayed on the Pump Overview Screen.
3
Current Pump Mode
Press Current Pump Mode to select "Linear Line Speed" or "Pressure Control". Then press the
BACK button to go to the appropriate screen.
4
Automatic Ramp Compensation (ARC) Button
Press to go to the Automatic Ramp Compensation screen.
5
Optional: Minimum Input Pressure
This field appears only if the pump is configured for a minimum input pressure lock.
The Minimum Input Pressure is a customer parametrizable value which has to be reached
for the according pumps on decentralized pump (Applicator or Metering Station) to be
released.
A plausible limit value of Input Pressure (a minimum pressure of not less than 2 bar is
recommended) has to be entered to avoid a dry run of the pumps; otherwise the pump can
be damaged.
6
BACK Button
Press to return to the previous screen.