3. Product Description
3.1 Components
The Programat CS comprises the
following components:
Furnace base with electronic
controls
Furnace head with firing
chamber
Firing table
Cooling tray
Power cord and hose for
vacuum pump
Vacuum pump (accessory)
3.2 Hazardous areas and safety equipment
Description of the risk areas of the furnace:
3.3 Functional description
The firing chamber may be heated up to max. 1200 °C (2192 °F) by
means of a heating element. Furthermore, the firing chamber has
been designed in such a way that a vacuum may be created with a
vacuum pump. The firing process is controlled with the
corresponding electronic controls and a software. Moreover,
the set and actual temperatures are continuously compared.
3.4 Accessories
(not part of the delivery form)
Automatic Temperature Checking Set 2 (ATK 2)
Programat Accessories Set (large and small firing trays, firing
tongs, Temperature Checking Set)
Vacuum pump
3.5 Indication/Contraindication
Indication
Glaze and crystallization firings (chairside area)
Contraindication
The Programat CS is not suitable as ceramic furnace for dental
laboratories
Description of the safety equipment of the furnace:
Safety equipment Protective effect
Protective conductor Protection from electrical shock
Electrical fuses Protection from electrical shock
Hazardous area Type of risk
Firing chamber Risk of burning
Opening/closing mechanism Risk of crushing
Electrical components Risk of electrical shock