EasyManua.ls Logo

IVT Greenline HT PlusC - Setting Desired Room Temperature; Extra Hot Water Functionality

IVT Greenline HT PlusC
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
FOR THE USER
Set the desired room temperature
If you have a room sensor connected to the heat pump you can set the
temperature in the room from the Room temperature menu. From Extra
functions (Customer level 2) you can also set how much you want the
sensor to infl uence the heating system.
This is what to do:
1. Press the Heat button in the initial menu.
2. Turn the menu dial clockwise until you reach the menu Room tempera-
ture.
3. Press the Adjust button.
4. Turn the menu dial clockwise to increase the room temperature.
Turn the menu dial anti-clockwise to lower the room temperature.
5. Save the new value by pressing the Save button.
Room temperature
10° 20,0 30°
Return Adjust
Note
The example describes how to set the
required room temperature with the
help of a connected room sensor. The
range is 10ºC to 30ºC.
Set the heat pump for extra hot water
You can obtain extra hot water by temporarily increasing the temperature
of the water in the hot water cylinder. The temperature increase is effected
with the help of the heat pump's electric cassette. A higher water tempe-
rature gives more hot water when, for example, a large number of people
wish to shower. The heat pump fi rst makes sure that the water reaches a
temperature of 50-55ºC. The electric cassette then continues to heat the
water to approximately 65ºC. You choose how long the function should run
using the Extra hotwater menu. This is what to do:
1. Press the Heat button in the initial menu.
2. Turn the menu dial clockwise until you reach the menu Extra
hotwater.
3. Press the Adjust button.
4. Turn the menu dial clockwise to choose the number of hours that the
electric cassette should be on (e.g. 24 hours).
5. Save the value by pressing the Save button.
When the set time has elapsed you
must repeat the setting to get extra
hot water again.
Note
Basic functions - Customer level 1
Extra hotwater
1h 24h 48h
Return Adjust
Extra hotwater
1h 24h 48h
Return Save