- 18 -
3.2 系统员参数表
3.2 System parameter table
参数编号
参数范围
典型值
参数描述
215
0/1
1
0关闭,1打开
222
0-1
0
取消电机自锁
242
0359
299
上停针位调整角度(相对于上针位传感器的位置偏
移)
244
0800
1
1启动机针保护传感器;其他值:放压脚延迟时间
ms;2针保护传器功关闭,建议参
141
249
110
2
剪线后自动抬压脚抬起保持时2min
260
0
0
拨线功能启用时改为2
263
0
0
拨线功能启用时改为2
1.Long hold keys to electricity, enter the technician 1xx parameter
table ;
2.And then press the key not to put at the same time, press the or
key, member can modify system parameter table 2xx;
3.Press the corresponding key number and change parameters, key
and key can modify;
4.Finally press the P button , that is, save and exit parameters setting
mode and return to normal sewing patterns.
Parameter number
range
values
Parameters to describe
215
0/1
1
0 is Off,1 is On
222
0-1
0
Motor lock disabled
242
0359
299
On the needle to adjust the angle
244
0~800
1
1 open the sensor Others Put the
presser foot delay time (ms)
249
1~10
2
Presser foot lift the hold time 2 min
260
0/2
0
Automatic sweep line switch,0 is off,2
is on
263
0/2
0
Automatic sweep line switch,0 is off,2
is on

Related product manuals