B
en-110
Safety, Operation, & Maintenance Manual
LDU ERROR CODES
Lithium
Sensor Supply Not Connected:
The sensor supply current is too low.
The limit is 0.000 A
Sensor Supply Reference Range:
The sensor supply reference voltage
is out of range. The valid range is
10.0V to 16.0V.
Sensor Supply Range:
The sensor supply voltage is out of
range. The valid range is 10.0V to
16.0V.
Dec Too High:
The change of sensor speed is too
high.
Wrong Direction / Plausibility Error:
The sensor and stator frequency have
different signs. Either the sensor sig-
nals need to be inverted or the motor
phase cables are connected incor-
rectly.
The sensor speed is too high, i.e. not
plausible/possible.
LDU Error Code Description
Caution
LED
Alarm
Sound-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
TRACTION
FAULT 7221
STEERING
FAULT 7221
3WD TRACTION
FAULT 7221
TRACTION
FAULT 7230
STEERING
FAULT 7230
3WD TRACTION
FAULT 7230
TRACTION
FAULT 7231
STEERING
FAULT 7231
3WD TRACTION
FAULT 7231
TRACTION
FAULT 7240
TRACTION
FAULT 7250
STEERING
FAULT 7250
3WD TRACTION
FAULT 7250