11.5  Filtration Modes for Spas
During the ltration/heating cycle the Jets pump 1 low speed will activate. 
To set a time for the rst ltration/heating cycle, simply turn power on to 
the spa two minutes prior to the desired time. Example: If you desire your 
rst ltration/heating cycle to begin at 10:00 AM turn off power to the spa 
and turn it back on again at 9:58 AM.
Note: Start time is approximate and may vary slightly from day to day.
Standard Filtration/Heating Modes (F1-F3)
(Heater automatically turns on during any heat call while in any Standard 
mode).
F1  4 hours of ltration/heating per day (one 2-hour cycle 
every 12 hours).
F2  6 hours of ltration/heating per day (one 2-hour cycle 
every 8 hours).
F3  8 hours of ltration/heating per day (one 2-hour cycle 
every 6 hours).
Economy Filtration/Heating Modes (F4-F6)
(Heater can only turn on during an active lter cycle while in 
any Economy mode).
F4  4 hours of ltration/heating per day (one 2-hour cycle 
every 12 hours).
F5  6 hours of ltration/heating per day (one 2-hour cycle 
every 8 hours).
F6  8 hours of ltration/heating per day (one 2-hour cycle 
every 6 hours).
Lock Modes (L1-L2)
L1  Lock Out (disables all spa functions to permit lter 
cleaning).
L2  Lock Mode (disables the jets and light buttons to 
prevent unauthorized use of spa). Filtration/heating 
cycle will continue to operate as programmed in 
this mode. The temperature display ashes when this function is 
enabled. Example: the “F3” ltration/heating cycle was enabled 
prior to choosing lock mode. The spa continues to perform the 
“F3” cycle until lock mode is canceled, allowing another cycle to be 
selected.
Note: To exit a Lock Mode you will need to re-enter the ltration/heating 
modes and select a cycle from F1-F6.
29