11.6  Programming the CLEARRAY (Ultraviolet) Water Purication 
System
A.  Programming the CLEARRAY System (U) or Corona Discharge 
Ozone (O3)
Press and hold the Jets pump 1 ( 
1
 ) and Cooler (   ) button at the 
same time for 3 seconds to enter the sanitizing system program. The 
screen will display one of the two menus below:
  CLEARRAY Menu  O3 Menu
1.  If the LED screen is displaying “U” then pressing the Jets pump 
1 will change the sanitizing system from “U” to “O3” and exit the 
programming menu. If the LED screen is displaying “O3” then 
pressing the Jets pump 1 will change the sanitizing system from “O3” 
to “U” and exit the programming menu.
Note: For the O3 option the “=” disables the duration countdown timer.
2.  If you do not wish to change the option do not press any buttons and 
after 10 seconds the display will return to the main menu.
Note: If the CLEARRAY System has been selected, when the  
time allotted has expired (365 days) the display screen will 
ash between the water temperature and “blb.” At this time the UV bulb 
must be replaced, the quartz tube must be cleaned and the duration 
countdown timer needs to be reset.
Press
or
Press
or