JWI-501
3-9-5
Zero: set auto zero. Default = 1e
When it displays ZEro, press <TARE>to enter. It displays ZEro x.x(x.x is auto zero
range:0.5d, 1d, 1.5d, 2d, 2.5d, 3d, 3.5d, 4d, 4.5d and 5d, d is division value when
n=3000). Press <SET/0~9> to choose. Press <TARE> to confirm and return weighing.
3-9-6
bUZZEr: set buzzle. Default = off
When it displays bUZZEr, press <TARE> to enter. Press <SET/0~9> to choose on or
off. on is using sound in upper and lower limit situation; off is without sound.
3-9-7
d: choose division. Default = 3000 division value
When it displays d,press <TARE> to enter. Press <SET/0~9> to choose division.
Press <TARE> to confirm, and there have three divisions of each capacity. When you
choose the little one, the speed of display will be slower.
3-9-8
on-rA: powering on range. Default=100
When it displays on-rA, press <TARE> to enter. It will show 100 which indicates
that no limit is imposed on the powering on range. In case the zero point upon
powering on is greater than 20% of the maximal weighing capacity, Err-0 and
Err-04 will be displayed upon powering on, and the tare should be reduced to less
than 20% of the maximal weighing capacity.
3-10
Brightness
Press and hold <ON/ZERO>. it displays lc-. Press <SET/0~9> to choose lu-1, lu-2.
lu-1 is save power mode (Recommend). Press <TARE> to confirm.
Default = lu-1
4 Calibration
1. Press <ON/ZERO> to turn on. After self-inspection, it comes into normal weighing
mode (no wind and quaking) and under zero;
2. Press <SET/0~9> together with <ON/ZERO> for 3 seconds,it shows the last
capacity. Press <SET/0~9> to choose c-30,c-60,c-150,c-300,c-600,c-1500,
c-3000,c-6000(c is capacity,unit is kg);
3. Press <TARE> to confirm;
4. Now it will show the offset value “0”. If it is not 0, press <ON/ZERO> to zero;
5. Place some standard weights on plate. After offset value is stable, press <TARE> to