Page 12
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual
 
 
Flow Meter
Pool pump
NOTE! Gate Valves are
optional on heater inlets
but will help system
balancing
Extend 12" past
end heater inlet
for hydraulic
balancing
2" pvc pipe
12 inches min. clearence around evap.
12"
Flow Meter
To Pool
Minimum 2" pvc
pipe
2" Gate Valve Bypass
OPTIONAL
2" pvc
Heater 1
Front of
Heater 2
Front of
Heater 3
Optional
Isolation Valves
From Filter
Manual Bypass Valve
2” PVC
3” PVC
Optional
Isolation Valves
From Filter
To Pool
Manual Bypass Valve
Optional
Isolation Valves
From Filter
To Pool
2” PVC
3” PVC

Table of Contents