Page 14
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual
 
BK
BR
W
BL
Y
BL
BK
BL
BL
Y
Y
BL
R
BK
R
BK
BL
BL
R
BK
Y
Y
BK
W
W
BK
BK
BK
BL
R
BR
BR/W
BK
R
BK
GR
GR/Y
GROUND
POWER BOARD
COMPRESSOR
FAN MOTOR
WATER PRESSURE
SWITCH
USER INTERFACE
REVERSING
VALVE
(OPTIONAL)
HIGH REFRIGERANT
PRESSURE SWITCH
LOW REFRIGERANT
PRESSURE SWITCH
CONTACTOR
W
W
W
W
W
L1
L2
L3
FAN CAPACITOR
FAN
RELAY
WATER
TEMP
DEFROST
TEMP
SENSOR
R
Y
Y
W
Y
W
FACTORY OPTIONAL 24 VAC
FACTORY 24 VAC HARNESS
FIELD INSTALLED 208/230 VAC
FACTORY INSTALLED 208/230 VAC
JE SERIES
230 VAC
THREE PHASE
60 Hz
WIRING DIAGRAM
JE 3000TR & JE3000TR3 ONLY