H0412200 Rev J
ENGLISH
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
Jandy Pro Series
JEP-R
Variable-Speed Pump Digital Controller
For use with Jandy Pro Series Variable-Speed Pumps
For Indoor or Outdoor Installations

Other manuals for Jandy Pro Series

Questions and Answers

  • S
    Susan GonzalezAug 15, 2025
    Why are my Jandy Swimming Pool Lighting colored lights out of sync?
    • J
      Jordan CrawfordAug 15, 2025
      If your Jandy Swimming Pool Lighting colored lights are out of sync, ensure proper wire connections. You can also try resetting all the lights to white by turning them off for five seconds and then turning them back on.
  • C
    Chad RobertsAug 18, 2025
    Why is my Jandy Swimming Pool Lighting blinking?
    • T
      Trevor ThomasAug 18, 2025
      If your Jandy Swimming Pool Lighting is blinking, it might be overheating. Make sure the light is fully submerged in water that does not exceed 104F (40C).
  • J
    john64Aug 22, 2025
    What to do if there is low water flow in my Jandy Water Filtration System?
    • V
      vrobinsonAug 22, 2025
      If you're experiencing low water flow in your Jandy Water Filtration System, start by checking and cleaning the skimmer and pump baskets, as the filter system strainer baskets may be dirty. Inspect all connections between the pool intake and pump for air leaks. Also, check all lines for debris or partially closed valves that could cause restrictions or blockages. Ensure the pool water level is above the pump inlet line. If the pump isn't primed, fill it with water at the basket and replace the lid. If the filter grids need to be cleaned or replaced, follow the instructions to do so.
  • M
    Michelle PatelAug 25, 2025
    How to stop dirt returning to the pool from my Jandy Water Filtration System?
    • J
      johnstonallisonAug 26, 2025
      If dirt is returning to your pool from your Jandy Water Filtration System, it could be due to a hole in the filter grid fabric, which requires replacing the filter grid. Another possibility is a worn o-ring seal inside the filter, which should be replaced. A cracked manifold can also cause this issue, so replace the manifold assembly.
  • J
    Jerry ShafferAug 28, 2025
    How to troubleshoot Jandy Swimming Pool Lighting when all lights fail to illuminate?
    • M
      Matthew UnderwoodAug 28, 2025
      If all Jandy Swimming Pool Lighting fails to illuminate, start by checking the 120VAC power supply into the transformer and verify there's a 12VAC output at the transformer. Check or reset the GFCI. Make sure 120 volts has not been used in the installation - if so damage is assured and is NOT WARRANTABLE.
  • J
    Jeremy MartinezAug 31, 2025
    What to do if one or more Jandy Swimming Pool Lighting are dim, blinking or not working?
    • S
      Stephanie BlackburnAug 31, 2025
      If one or more of your Jandy Swimming Pool Lighting are dim, blinking, or not working, it might be due to a poor connection or improper wire gauge. Separate each light and independently wire 12V to the single light only, repeating this process for each light. If a junction box is used, check for proper connection of the light cord and verify the correct wire gauge is used between the transformer and junction box.
  • A
    Andrea MathisSep 3, 2025
    Why is the water not clear in my Jandy Water Filtration System?
    • K
      Kendra McintyreSep 4, 2025
      If the water in your Jandy Water Filtration System is not clear, several factors could be responsible. It might be due to an insufficient disinfectant level, which requires checking and adjustment. Incorrect pool chemistry also plays a role, so test and adjust the water chemistry. Heavy use or dirt loads may necessitate adjusting the filter time or water chemistry. Insufficient running times require increasing pump run time. A dirty filter needs backwashing, and a hole in the filter element means the filter grids must be replaced.
  • J
    Jessica HortonSep 7, 2025
    What causes high pressure on start-up in Jandy Water Filtration Systems?
    • D
      Daniel HawkinsSep 8, 2025
      High pressure on start-up in your Jandy Water Filtration System can be attributed to a few reasons. A small eyeball fitting in the pool or spa may be the cause, and replacing it with a larger diameter fitting might resolve the issue. Check for partially closed valves on the return line and ensure they are fully open. Also, the pump might be too large, so verify the pump and filter selection. Lastly, dirty filter grids can contribute to high pressure, so clean them as per the instructions.
  • T
    Tamara MillerSep 12, 2025
    Why does my Jandy Water Filtration System have short filter cycles?
    • A
      Amy CollierSep 12, 2025
      Short filter cycles in your Jandy Water Filtration System can occur due to several reasons. The presence of algae clogging the filter is a common cause, so check the disinfectant content. Incorrect water chemistry, specifically pH, total alkalinity, and TDS, can also lead to this issue. Ensure strainer baskets are being used and are not broken; replace them if necessary. The pump output exceeding the design flow rate of the filter can also cause short cycles, so check the pump performance. Ineffective cleaning is another factor, so clean or replace the filter grids as per the instructions.

Summary

Important Safety Instructions

General Safety Instructions

General safety precautions for electrical equipment installation and use.

Spa and Hot Tub Safety Guidelines

Safety guidelines for spa and hot tub water temperature and usage.

General Safety Warnings and Precautions

Pressure Testing and Electrical Hazard Warnings

Warnings covering pressure testing, electrical hazards, pump operation, and water systems.

Pump Operation Cautions

Caution against running the pump dry to avoid damage and voiding the warranty.

Spa Usage and Equipment Safety

Additional Spa Safety Advice

Additional safety advice for spa and hot tub usage and heater control systems.

Pool Pump Suction Entrapment Prevention

Suction Hazard Warnings and Guidelines

Warnings about suction hazards and guidelines for safe suction outlet installation.

Digital Controller Installation

Controller Installation Introduction

General instructions for installing the JEP-R Variable-Speed Digital Controller.

Controller Panel Overview

Overview of the controller panel functions and speed controls.

Controller Wiring and Mounting

Backplate Installation Procedures

Step-by-step instructions for mounting the backplate to an electrical box or flat wall.

Connection to Variable-Speed Pump

Procedure for connecting the controller to the variable-speed pump.

Pump Communication and Remote Control Setup

Pump Wiring and DIP Switch Settings

Detailed steps for wiring the RS-485 cable and setting DIP switches.

Connection to Remote Contacts

Instructions for connecting remote contact closures to control pump speeds.

User Operation of the Variable-Speed Controller

Manual Pump Control and Timed Programs

Timeclock Setup and Operation

How to create and manage timed pump programs using the controller.

Keypad Lock and Service Setup Entry

Service Setup: Pump Speed and Defaults

Jandy Pro Series Specifications

General IconGeneral
BrandJandy
ModelPro Series
CategoryController
LanguageEnglish

Related product manuals