EasyManua.ls Logo

Jandy TruDose - User Manual

Jandy TruDose
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state or
local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be followed exactly. Before
installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death. DO NOT MODIFY THIS EQUIPMENT.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/
operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
ENGLISH | FRANÇAIS | ESPAÑOL
H0751300_REVF
WARNING
Periodically use an independent pH and Chlorine test kit to verify safe pH and chlorine levels. If the pH, Oxidation
Reduction Potential (ORP) or Flow Cell sensors are damaged, dirty, contaminated, or otherwise malfunctioning;
inaccurate results may be reported to the monitoring system resulting in improper water chemistry that may result in
property damager, personal injury, or death.
TruDose
TM
Chemical Controller
pH 7.2-7.6
ORP 600-800 mV

Table of Contents

Questions and Answers

  • M
    Melinda FloresAug 16, 2025
    How to fix high chlorine level in Jandy TruDose Controller?
    • J
      Jon CollinsAug 16, 2025
      To address a chlorine level that's too high in your Jandy Controller system, start by checking chlorine and cyanuric acid levels with a test kit. Adjust the ORP set level as needed. Also, ensure the sensor tip is clean by following the maintenance instructions. If the pH is too high, measure it and consider cleaning or replacing the pH sensor.
  • P
    pacepatriciaAug 18, 2025
    How to increase chlorine level in Jandy TruDose Controller?
    • R
      Richard CardenasAug 18, 2025
      If the chlorine level is too low in your Jandy Controller, check the ORP set level and adjust if necessary after testing the chlorine level with a test kit. Inspect the saltwater chlorinator and its cell. Increase daily filtration time if it's too low. Clean or replace the sensor if it's malfunctioning. Also, adjust the pH to between 7.2 and 7.6 if it is too low.
  • E
    Elizabeth TaylorAug 21, 2025
    How to decrease pH level in Jandy Controller?
    • E
      Erin WrightAug 21, 2025
      To address a pH level that is too high in your Jandy Controller, begin by cleaning the pH sensor tip according to the maintenance instructions. Then, adjust the pH calibration if it's improper. Refill the pH chemical feeder if it's empty and repair the feed pump if it's malfunctioning. Also, increase the dose time and check/adjust alkalinity.
  • S
    Sheri MooreAug 25, 2025
    How to increase pH level in Jandy TruDose Controller?
    • N
      Noah MoralesAug 26, 2025
      To resolve a pH level that's too low in your Jandy Controller, start by checking the pH level with a test kit and adjust the set level as needed. Reduce the pH dose time, and calibrate, clean, or replace the pH sensor if it's malfunctioning. Check and adjust the alkalinity and ensure proper dilution of muriatic acid (4:1 dilution).
  • A
    Anthony Wells MDAug 27, 2025
    What to do if ORP alert LED is blinking on Jandy Controller?
    • N
      Nicholas OrrAug 28, 2025
      If the ORP alert LED is blinking on your Jandy Controller, indicating that the ORP is lower than 390 mV or higher than 910 mV, verify that chlorine was not manually added. Also, verify that the saltwater chlorinator powerpack and cell work properly. Check for proper valve positions and leaks in chlorine lines.
  • M
    Michael Rogers PhDAug 31, 2025
    What does it mean when the pH alert LED is blinking on Jandy TruDose Controller?
    • J
      Jamie BrooksAug 31, 2025
      If the pH alert LED is blinking on your Jandy Controller, indicating that the pH is lower than 6.9 or higher than 8.1, verify the acid tank is not empty. Increase the dosing time if the controller is undershooting the set level. Verify the acid was not manually added; if it was, dilute the acid with water or lower the dosing time.
  • B
    Brandon AndersonSep 2, 2025
    What does error Er2 mean on Jandy Controller?
    • A
      Anthony WeaverSep 3, 2025
      If the ORP alert LED is ON and "Er2" is displayed on the LCD screen of your Jandy Controller, it means the ORP overfeeding alert is ON and the setpoint has not been reached after the set chlorination time. To solve this, check the saltwater chlorinator and its cell, increase the overfeed alert time, and calibrate, clean, or replace the ORP sensor. Also, lower the cyanuric acid concentration in the pool and increase daily filtration time. Refer to the "pH level is too high" section.
  • D
    David PetersonSep 6, 2025
    What does error Er1 mean on Jandy Controller?
    • J
      Jay SmithSep 6, 2025
      If the pH alert LED is ON and "Er1" is displayed on the LCD screen of your Jandy Controller, indicating a pH overfeeding alert is ON and the setpoint has not been reached after 60 dosing cycles, refill the chemical feeder, increase the pH dose time, calibrate, clean, or replace the pH sensor, check and adjust alkalinity, and repair the feed pump.
  • M
    Melanie BarkerSep 8, 2025
    Why is the display off on my Jandy TruDose?
    • R
      Raymond FergusonSep 9, 2025
      If the display and LEDs are off on your Jandy Controller, the cause is likely no power supply. Check the circuit breaker.
  • D
    dsullivanSep 12, 2025
    What to do if feeder is not operating on Jandy TruDose Controller?
    • M
      Misty MooreSep 12, 2025
      If the feeder is not operating on your Jandy Controller, check the flow through the flow cell and controller to ensure adequate flow.

Summary

Important Safety Instructions

Safety Instructions

Essential safety precautions for installation and use of the controller.

Getting Started

System Components

Overview of the TruDose Chemical Controller and its associated parts.

Specifications

Technical details and physical dimensions of the controller unit.

Controller Panel Descriptions

Explanation of the controller's display, LEDs, and button functions.

Connecting to Saltwater Chlorinator

Guide for integrating the TruDose controller with Jandy Saltwater Chlorinators.

Installation

Setup

Initial steps and preparations before the physical installation process.

Tools

List of necessary tools for performing the installation.

Power Supply

Requirements and guidelines for connecting the controller to a power source.

Controller Installation

Steps for physically mounting and positioning the main controller unit.

pH and ORP Sensors Installation

Instructions for correctly installing the pH and ORP water sensors.

Chemical Pump Installation

Procedures for installing the chemical dosing pump and associated tubing.

Bonding

Electrical bonding requirements for pool equipment and safety standards.

Startup and Shutdown

Water Chemistry

Recommended water chemistry parameters for pool and spa maintenance.

Startup

Procedures for the initial power-up and configuration of the controller.

Shutdown

Steps for safely powering down and deactivating the controller.

Modes and Adjustments

Explanation of operating modes like Auto, pH, and ORP settings.

FCC Regulatory Compliance Statement

Connecting to TruClear XL Saltwater Chlorinator

Maintenance

Winterizing (extended shutdowns or colder climates)

Procedures for preparing the controller for seasonal storage or cold weather.

Cleaning the sensor tips

Instructions for cleaning the pH and ORP sensor tips for accurate readings.

Checking the pH Sensor

Steps to verify the accuracy and function of the pH sensor.

Checking the ORP Sensor

Steps to verify the accuracy and function of the ORP sensor.

Chemical Pump Tube Replacement Procedure

Preparation

Safety precautions and initial steps before replacing pump tubes.

Remove Tube

Detailed instructions for safely removing the old pump tube from the mechanism.

Install New Tube

Instructions for correctly installing a new pump tube into the mechanism.

General Troubleshooting

Chlorine level too low

Potential causes and corrective actions for low chlorine readings.

Chlorine level too high

Potential causes and corrective actions for high chlorine readings.

pH level is too low

Potential causes and corrective actions for low pH readings.

pH level too high

Potential causes and corrective actions for high pH readings.

pH alert LED blinking

Troubleshooting pH alert indicators and error codes.

ORP alert LED blinking

Troubleshooting ORP alert indicators and error codes.

Display and LEDs off

Diagnosing issues related to the controller's display and indicator LEDs.

Feeder not operating

Identifying and resolving problems with the chemical feeder function.

Flow LED off

Troubleshooting why the flow indicator LED is not illuminated.

pH alert LED ON and Er1 displayed

Specific troubleshooting for pH overfeeding alerts and 'Er1' error.

ORP alert LED ON and Er2 displayed

Specific troubleshooting for ORP overfeeding alerts and 'Er2' error.

Chemical Pump Tube Troubleshooting

Tube leaking

Diagnosing and fixing leaks in the chemical pump tube.

Tube life is shortened

Identifying causes and solutions for reduced pump tube lifespan.

Tube connection is leaking

Troubleshooting leaks at the connections of the pump tube.

Jandy TruDose Specifications

General IconGeneral
BrandJandy
ModelTruDose
CategoryController
LanguageEnglish