To set the minimum speed, from the service setup menu,
select
SET MIN LIMIT using the arrow keys. Press
MENU. Using the arrow keys, set the minimum speed to
the desired value. Press
MENU to accept and store.
2
3
4
SET MIN LIMIT
RPM: 600
MENU
To set the maximum speed, from the service setup
menu, select
SET MAX LIMIT using the arrow keys.
Press
MENU. Using the arrow keys, set the maximum
speed to the desired value. Press
MENU to accept and
store.
2
3
4
SET MAX LIMIT
RPM: 3450
MENU
4.3 Load Defaults
To restore factory default settings to the controller, from
the service setup menu, select
LOAD DEFAULTS. Press
MENU. Using the arrow keys, select YES. Press MENU
to restore factory default settings.
2
3
4
LOAD DEFAULTS
YES
MENU
Default Speeds
eStar 1750 RPM
Speed 2 - 8 2750 RPM
Priming Speed 2750 RPM
Other Defaults
Freeze Protect Duration 30 min
Priming Duration 3 min
4.4 Last Fault
This feature shows on the top display line, the most
recent unique fault message and on the bottom display
line, the second-to-last unique fault message. If there
is no entry for a fault, the display will show “*---------
-------*” on the corresponding line. To select last fault,
from the service setup menu select
LAST FAULT. Press
MENU.
NOTE The fault messages are stored in non-volatile
memory, and remain even with no power. To
clear the fault history, press either arrow key.
2
3
4
SELECT SERVICE SETUP
LAST FAULT
MENU
4.5 Priming Speed and Duration
The controller will command the variable-speed pump
to operate at the priming speed for the priming duration
specied (except during timer program overlaps or
follow-on commands where the pump is not stopped
before changing speeds). From the service setup menu,
select
PRIMING using the arrow keys. Press MENU.
2
3
4
PRIMING DURATION
MIN: 3
MENU
To set priming speed, select PRIMING SPEED using
the arrow keys. Press
MENU. Using the arrow keys, set
the priming speed to the desired value. Press
MENU to
accept and store.
2
3
4
PRIMING SPEED
RPM: 3450
MENU
PAGE 14
JEP-R Variable-Speed Pump Controller
|
Installation Manual
ENGLISH

Other manuals for Jandy Pro Series