Loading...
10
(C)
(A)
(B)
(D)
(E)
(F)
6.0 mm
MECHANICAL ADJUSTMENT
PRESSER BAR HEIGHT AND ALIGNMENT
TO CHECK:
1. Raise the presser foot lever (A).
2. The distance between the presser foot (D) and the needle plate (E) should be 6.0 mm (0.24").
ADJUSTMENT PROCEDURE:
1. Remove the face cover (See page 4).
2. Raise the presser foot lever and loosen the setscrew (C) on the presser bar holder.
Adjust the distance between the presser foot (D) and the needle plate (D) to 6.0 mm (0.24").
3. Tighten the setscrew (C) securely.
4. Tighten the setscrew (B) to secure the lamp socket.
5. Attach the face cover.
NOTE: When you tighten the setscrew (B), make sure that both sides of the
presser foot are parallel to the feed dog slots (F) on the needle plate.