12.TAKE-UP SPRING REPLACEMENT AND SETTING
Check : 1. Open face cover.
2. Check to this "take-up spring", in normal it
should touch to (A) , and take-up spring
should be 1~1.5 mm (B).
3. When this spring in operation (Lift in arrow
direction) tension be 6g~12g.
Adjustment : 1. Loosen set screw (C).
2. Turn the spring (D).
In clockwise to increase tension.
In counter clockwise to decrease tension.
Adjust until this spring tension reaches
6g~12g.
3. Tighten set screw (C).
6g~12g
D
C
B
1
~
1
.
5
m
m
A
C
14
(ALL MODELS)