52
Needle plate replacing bar
4. Turn the power switch ON while pressing the Start/Stop
button and the Reverse stitch button to enter the factory
setting mode.
Press "Other sensor" key.
5. Be sure that "Straight" indicates "L", and "ZigZag" indicates
"H" when the needle plate is attached.
6. Replace the needle plate with the needle plate for straight
stitch. Be sure that "Straight" indicates "H", and "Zigzag"
indicates "L".
If not, adjust the micro switch base plate position (see page
50).
* To remove the needle plate, press the needle plate
replacing bar in the direction of arrow with a screwdriver.
Needle plate attached:
Needle plate for straight
stitch attached: