"Welding Mode" when in Welding Engineer Mode .
1) If the "Welding Mode" is MIG, set the MIG
post-flow time, with range 0-5.0, accuracy of 0.5, and
unit of seconds.
2) If the "Welding Mode" is Lift TIG, set the Lift TIG
post-flow time, with range 0-10.0, accuracy of 0.5,
and unit of seconds.
Set the Lift TIG downslope time, with range 0-5,
accuracy of 0.5, and unit of seconds.
Set the MIG burn back voltage, with range 10-20,
accuracy of 0.1, and unit of voltages.
Set the MMA hot start current, with range 0-60,
accuracy of 1, and unit of amperes.
Set the slow wire feed speed of MIG; can be set to
"0", "1", "2" or "3".
1) "0" indicates that the slow wire feed function is
disabled.
2) "1", "2" or "3" indicate that the slow wire feed
speed is 1/3, 1/2 or 2/3 of the current set speed,
respectively.
Can be set to "0" or "1" to use wireless or wired
remote controller.
1) "0" indicates wireless remote controller.
2) "1" indicates wired remote controller.
Note! If entering the Welding Engineering Mode from different "Welding Mode" states,
the functional definition corresponding to the background parameters/functions may
be also different! For example: If entering the Welding Engineering Mode background
from the MIG welding mode, the pre-flow/post-flow time set are the pre-flow/post-flow
time of MIG mode.
Note! Some models do not support F09. Please confirm with the seller whether the
machine supports this function before purchasing.