When the short circuit is cleared, the welding current will automatically return to the
set current.
7.2.5 Turn off the power supply after welding
(Same as section 7.1.7)
The power switch is located on the rear panel of the machine and set it to the "OFF" position.
After a time delay, the panel indicator is off and the welder stops working.
7.3. Lift TIG operation
7.3.1 Turn on the power switch
(Same as section 7.1.1)
7.3.2 Select Lift TIG welding mode
(Lift TIG mode)
Press the "Welding Mode Selection" key to select Lift TIG mode.
7.3.3 Set welding parameters
Use "Parameter Adjustment Knob A" to set the "Welding Current".
Choose the appropriate welding current, tungsten electrode and shielding gas flow based on
the actual situation. For details, refer to the following data.
Selection of parameters for manual TIG welding stainless steel plate
Tungsten
diameter
(mm)
Thickness of
stainless steel
plate (mm)
Maximum current
(A)
Maximum argon
flow rate (l/min)
1~2
1~3
50
5
50~80
6
2~4
3~6
80~120
7
121~160
8
161~200
9
201~300
10