· The contact tip is
seriously worn out
· The liner in the
welding torch is
seriously worn out
· The welding wire is
of poor quality
· Replace the liner in the welding torch
· Replace with qualified welding wire
Please contact the maintenance
personnel of Shenzhen JASIC
Technology Co., Ltd.
Elimination of general problems in MMA
Fan does not rotate or
rotates abnormally after
power on
The ambient
temperature is too low
or the fan has been
damaged
When the temperature is too low, leave
the machine to operate for a while. The
temperature in machine will rise then
fan will resume normal operation. If it is
still not working, it is necessary to
replace the fan.
The power cord is not
connected properly
The rated current of
the electrode holder is
too low
Change the electrode holder with a high
current one
Arc is easily
interrupted
Use after the mains power is normal
Please contact the maintenance
personnel of Shenzhen JASIC
Technology Co., Ltd.
Elimination of general problems in Lift TIG
Fan does not rotate or
rotates abnormally after
power on
The ambient
temperature is too low
or the fan has been
damaged
When the temperature is too low, leave
the machine to operate for a while. The
temperature in machine will rise then
fan will resume normal operation. If it is
still not working, it is necessary to
replace the fan.