70
6. The room is now free to move.
Using either a 5/8” or 3/4” wrench or
socket, crank the room either in or
out completely. If the slideout system
is supplied with a gearbox override
(optional), use the crank handle to move
the room.
7. When the rooms is fully in or out have
one person apply pressure to the wrench/
ratchet and return the brake lever to its
engaged position. This ensures the
room is locked into a sealed position.
8. Install the transit bars (if so equipped) to
the slideout room and take the unit to an
authorized dealer for service.
Refer to the Power Gear® Electric Slideout Operation Manual for detailed operation, safety
and troubleshooting information.
The Power Gear® Slim Rack slideout is typically used for
slideouts 144” long and longer.
It is operated by a 12VDC electric motor.
The system is equipped with a manual override allowing
the room to be extended / retracted in the event of a power
loss.
The system has a controller (Fig 1) with programmable
stops that stop the motor when the room is fully extended
or retracted.
The controller has the ability to detect faults for easier troubleshooting.
A wall mounted touchpad allows room movement and provides end user feedback.