EasyManua.ls Logo

Jayco Hummingbird 2018 - Operating the Slideout

Jayco Hummingbird 2018
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

71

The slideout will not function until the stops are properly set or
faults are cleared.
 indicates room movement.
with the system.
(Refer to the Fault Diagnostics / Troubleshooting).

To ensure ample voltage is being supplied to the slideout
system motor, power should be supplied from one of the
following sources:
Attach the RV to shore power.
Have the motor home engine running.
Turn on the generator.

1. Engine or generator must be running, or plugged into
shore power.
2. Transmission must be in park or neutral (if applicable).
3. Set the parking brake and level the unit.
4. Remove transit bars (if so equipped) if extending the
room; install if retracting.
5. Turn  the on/o switch or key.
6. Press and hold the OUT button (Fig 4). To retract, press
and hold the IN button. There will be a slight delay
before the room begins moving.
7. The GREEN LED should be solid ON when room is in
motion.
8. Release the OUT button when the room is fully extended
or the IN button when fully retracted, and stops moving.
9. Turn  the on/o switch or key.

The control has the ability to detect and display several faults. When a fault is detected,
room movement stops and two dierent LEDs will ash in a pattern.
The RED FAULT CODE LED (Fig 4) will ash a number of times corresponding to a
specic fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will ash GREEN a number of times
corresponding to which motor has the associated fault.
Example: (4) RED ashes and (2) GREEN ashes indicate a motor fault on motor 2.
; faults must be cleared for the room to operate normally.
 faults can be cleared by pushing and releasing theor buttons on the
wall touchpad (Fig 4).
 faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).



Table of Contents