EasyManua.ls Logo

Jayco PINNACLE - Page 123

Jayco PINNACLE
187 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
113
PLUMBING SYSTEM
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
9#40+0)
NOTE:It is important that once the RV has returned to lower eleva-
WLRQEHORZIHHWDQ\KLJKDOWLWXGHGHUDWLRQRURWKHUDGMXVWPHQWV
be reversed for proper operation of the water heater.
combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
SURSHUGHUDWLQJRIWKHZDWHUKHDWHU&KDQJHRXWRIWKHRUL¿FHGHUDWLQJVKRXOGEHGRQHE\
WKHGHDOHURUDTXDOL¿HGVHUYLFHDJHQF\
Pressure & temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1. Turn off the water heater.
2. Turn off the cold water supply line.
3. Open a faucet in the recreation vehicle.
4. 3XOORXWWKHKDQGOHRIWKHSUHVVXUHUHOLHI37YDOYHDQGDOORZZDWHUWRÀRZIURPWKH
valve until it stops.
5. Release the handle on the P&T valve - it should snap closed.
&ORVH WKHIDXFHW DQG WXUQ RQ WKH FROG ZDWHU VXSSO\$V WKHWDQN ¿OOV WKH DLUSRFNHW ZLOO
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Maintenance
'RQRWDOORZWKHEXUQHUWREXUQZLWKD\HOORZÀDPHRUFRQWLQXHWRRSHUDWHWKHZDWHUKHDWHU
ZLWKDQLPSURSHUEXUQHUÀDPH
Periodically, inspect the water heater vent for soot. Soot is a sign of incomplete combustion
and must be corrected before operating the water heater. This is your visual warning that the
water heater is operating in an unsafe manner.
,IVRRW LVSUHVHQW LPPHGLDWHO\VKXW WKHXQLW GRZQDQG FRQWDFW\RXU GHDOHU RUD TXDOL¿HG
service agency.
Table
of
Contents
Table of Contents
Maintenance
Record
Maintenance Record

Table of Contents

Related product manuals