EasyManua.ls Logo

JBL SUB200 - Page 4

JBL SUB200
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Specification Unit
QA Test
Limits Conditions Notes
ATO Turn-on time 5 ms
Functional
Amp connected and AC on, then input
signal applied
Auto Mute/ Turn-OFF Time 15 minutes
Functional
T before muting, after signal is
removed Auto turn of time (T) must be 10 > T <15
Power on Delay time 3 sec.
Functional AC Power Applied
Transients/Pops
ATO Transient 5 mV-peak
10 @ Speaker Outputs
Turn-on Transient 50 mV-peak
100 @ Speaker Outputs AC Line cycled from OFF to ON
Turn-off Transient 50 mV-peak
100 @ Speaker Outputs AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power 12 Watts
13 @ nom. line voltage
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
Power Cons.@rated power 180 Watts
187 @ 120V-60 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Power Cons.@rated power 195 Watts
200 @ 230V-50 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection YES --
Functional Direct short at output
Thermal Protection 65 deg. C --
Functional @1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection YES --
Functional DC present at Speaker Out leads Relay or crowbar (for driver/fire
Line Fuse Rating
120VAC 2.5 Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
230VAC 1.25 Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
SUB200 (SCS200.7sys)