Parameter Specification Unit
QA Test
Limits Conditions Notes
ATO Turn-on time 5 ms
Functional
Amp connected and AC on, then input
signal applied
Auto Mute/ Turn-OFF Time 15 minutes
Functional
T before muting, after signal is
removed Auto turn of time (T) must be 10 > T <15
Power on Delay time 3 sec.
Functional AC Power Applied
Transients/Pops
ATO Transient 5 mV-peak
10 @ Speaker Outputs
Turn-on Transient 50 mV-peak
100 @ Speaker Outputs AC Line cycled from OFF to ON
Turn-off Transient 50 mV-peak
100 @ Speaker Outputs AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power 12 Watts
13 @ nom. line voltage
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
Power Cons.@rated power 180 Watts
187 @ 120V-60 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Power Cons.@rated power 195 Watts
200 @ 230V-50 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection YES --
Functional Direct short at output
Thermal Protection 65 deg. C --
Functional @1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection YES --
Functional DC present at Speaker Out leads Relay or crowbar (for driver/fire
Line Fuse Rating
120VAC 2.5 Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
230VAC 1.25 Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
SUB200 (SCS200.7sys)