OPERATION
REVIEW A PROGRAM (Figure1)
13
1Turnthepowerswitchon
2PressPROGRAMNUMBER
3PresstoselecttheprogramnumbertobereviewedThePROGRAMNUMBER(P1-P30)
willappearontheMainDisplay
4 The number of stages in the program are indicated by the STAGE lights next to the Main Display
5PressENTER/REVIEWNIGHTTIME(DELAYSTART)lightturnsonThenumberofhoursenteredforthe
entireprogramtobecompletedandreadytocastappearsontheMainDisplayAfter7seconds,ifno
otherbuttonispressed,NIGHTTIME(DELAYSTART)lightturnsoffandtheactualfurnacetemperature
appearsontheMainDisplay
6PressENTER/REVIEWagainIf7secondshasnotelapsed,theHEATRATElightturnsonIf7seconds
hasalreadyelapsedandthefurnacetemperatureappearsontheMainDisplay,pressENTER/REVIEW
twiceFirsttheNIGHTTIME(DELAYSTART)lightturnsonandthentheHEATRATElightturnsonWhenthe
HEATRATElightison,theprogrammedheatrateappearsontheMainDisplay
NOTE: STAGE 1 light is now on.
7PressENTER/REVIEWandTEMPlightturnsonTheprogrammedtemperature(TEMP)forSTAGE1
appearsontheMainDisplay
8PressENTER/REVIEWandHOLDTIMElightturnsonTheprogrammedHOLDTIMEforSTAGE1
appearsontheMainDisplayinHR:MIN
9AlloftheinformationinSTAGE1hasnowbeenenteredIfENTER/REVIEWispressedagain,STAGE2
lightturnsonReviewSTAGE2followingthesameprocedureasaboveContinuepressingENTER/
REVIEWtoreviewalloftheindividualparametersinSTAGE2,3,or4
NOTE: NIGHT TIME (DELAY START) appears only at the very beginning of STAGE 1.