High / Low Activity of PLC outputs
-> refer chapter 4.4 Output Configuration
Set PLC output to logic 1 (level according, SOA)
Equivalent to SO, but set all outputs binary coded
Bit 0 = Output 1, Bit 1 = Output 2
Clear output (level according, SOA)
Status all Outputs,
0= logic 0, 1=logic 1
Status all Outputs in HEX format
Preload output number for output function assignment with
command TYOF
Assign type of output function to the with NOF preloaded
output number (0 = no function, 1 = REF, 2 = INMO, 3 = EDPG,
4 = TGR, 5 = ERR, 6 = BRK, 7 = INPO, 8 = IFML, 9 = IFSE,
10 = INSE, 11 = INFO, 12 = WARN, 13 = INFM)
Trigger upward counting, absolute, at output #x defined in
Output-Function, pulse during 5ms
± 2'000'000'000 Increment
Trigger downward counting, absolute, at output #x defined in
Output-Function, pulse during 5ms
± 2'000'000'000 Increment
0=all Input HIGH active, 1= all Input LOW active,
2= individual input activity selection according to ILAS (value 0
and 1 puts ILAS to 0x0 respectively 0xF)
individual input activity selection, 0=Input HIGH active,
1=Input LOW active
Hex value binary coded for input 1-4 (values 0x0 and 0xF put
ILA to 0 resp. 1. All other values are to 2 by ILA
Status all inputs, 0 = Low, 1 = High
/ ? incl. indication of input number
Status single input, 0 = Low 1 = High
Status all Inputs in HEX format
Preload input number for input function assignment with
command TYIF
Assign type of input function to the with NIF preloaded input
number (0 = no function, 1 = REF, 2 = IX, 3 = PG, 4 = SO, 5 = CO,
6 = JP, 7 = JN, 8 = CPOS, 9 = IP, 10 = SI, 11 = SIC, 12 = LS-,
13 = LS+,14 = EE, 15 = EE1, 16 = PWC, 17 = PRF, 18 = RSTO,
19 = OVRD, 20 = PGEX, 21 = DIF, 22 = PQ)
Parameter A of input function of with NIF preloaded input
number (value depending on input function, according to value
described in chapter 9.13.1 Selection of Input Functions)
Parameter B of input function of with NIF preloaded input
number (value depending on input function, according to value
described in chapter 9.13.1 Selection of Input Functions)
Parameter C of input function of with NIF preloaded input
number (value depending on input function, according to value
described in chapter 9.13.1 Selection of Input Functions)
Shows present position captured with input
Shows the position captured with input 4
Set all 8 capture Position Register to 0