EasyManua.ls Logo

Jetco Torque Tools ED SERIES - Page 13

Jetco Torque Tools ED SERIES
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
CR at end
CR at end
12Jetco Torque Tools
Description
LIST OF ASCII COMMANDS
ExmapleCommand
DTC
ETC
Return calibration full scale torque
Return current peak CW torque value
Return current peak CCW torque value
Enable Options Changes
RFS
CLP
ALP
ENB
Command: ENK,1,0,1,1<CR>
Enables:
Units Changes
Target Changes
Target Tolerance Changes
Disables:
Mode Changes
Response: OK
Get: CR at end or ? CR at end
Set: KEY,1,1,1,1 CR at end
Position 1 = Units Change, 1 = Enabled,
0 = Disabled
Position 2 = Mode Change
Position 3 = Target Change
Position 4 = Target Tolerance Change
Enable / Disable Keypresses.
Stores setting in EEPROM
ENK
Command: RFS?<CR> or CLP<CR>
Response: Calibration full scale torque in
ASCII
Command: CLP?<CR> or CLP<CR>
Response: Current peak CW torque value
Command: ALP?<CR> or ALP<CR>
Response: Current peak CCW torque value
Command: ENB<CR>
Response: OK
Get: CR at end or ? CR at end
Get: CR at end or ? CR at end
Get: CR at end or ? CR at end
CR at end
Disable target changes.
Allows viewing only.
Enable target changes.
Command: DTC <CR>
Response: OK
Command: ETC <CR>
Response: OK
www.itorque.com