COMPLEX RADIO CONTROL SYSTEM
telemetry information with configuration possibilities of
equipment connected to this bus, for instance by a DC/DS
transmitter. This interface is physically accessible at the receiver
output labeled „Ext.. This configuration type is used, for instance,
when receivers are connected for example to Central Box.
JETIBOX, UDI - serial data output suitable for connection of
devices with unidirectional UDI interface (e.g. VBar).
OutputChannelCnt - setup of generated number of receiver
outputs. If the receiver receives less channels than selected in
setup, the remaining channels will be replaced by a throw specified
by the Fail Safe value for individual channels. Otherwise, the
number of output pulses will be reduced to the setup number.
PPM-UDI Mode - data conversion mode can be:
Direct
ź output PPM signal contains data directly from the transmitter,
without conversions and channel mapping
ź conversions and possible channel mapping are applied to
output servo impulses only
ź different channels might be assigned to the PPM signal and
servo output pins
Computed
ź conversions and prospective mappings are applied to output
servo impulses and also to PPM signal
ź servo impulses and PPM signal contain the same information
EN