USR-TCP232-410S User Manual
25 / 46
4.1.11 KeepAlive
When 410S’ network is abnormal, it can judge the status in time and disconnect. And connect to server
once network recovers.
4.1.12 Modbus RTU to Modbus TCP
Settings:
1. Open USR-TCP232-M4,E45 Setup Software, set 410s TCP server/TCP client mode.
2. Select “ModbusTCP”
3. Click to save the parameter
Modbus TCP Configuration
4.1.13 Device ID
The function have 2 types: send ID once connection and send ID once sending data. It is used to
condition that need register packet or need packet header/tail for normal transmission.