USR-TCP232-410S User Manual
34 / 46
4. Return results of save settings command
If settings are correct, it returns:
FF 01 04 4B
5. Return results of basic settings command
FF 01 05 4B
6. Others return results
Sum check fault returns 'E' + right parity
Correct execution: FF 01 CMD 'K'
User name/password fault returns: FF 01 CMD 'P'
Others faults return: FF 01 CMD 'E'
4.2.2 Serial Setting Protocol
Serial AT commands, please wait for updating.
5. Parameter Configuration
It is setup software configuration, webpage configuration and serial configuration.
How to configure:
Revise user name/password→set IP access method→serial parameter→410S work mode→work mode
related parameter
5.1 Software Configuration
To make sure setup software normal running, please check the below firstly:
1. 410S and setup software PC are within same LAN.
2. Close the anti-virus software and firewall on PC.
3. Disable network card nothing to do with this testing.
Download [USR-TCP232-M4&E45] Setup software here:
http://www.usriot.com/usr-tcp232-m4e45-setup-v2-3-0-78/
Search device and all 410S within LAN can be found. It includes IP, name, MAC and version#.