A19A
Issue 03/03/2003
Catalogue Section 1 © 2003 Johnson Controls Inc.
Order No. PD-A19A-E
4
T
ype number selection table:
Range
( °C)
Diff.
(K)
Bulb
style
Setting
(see page 2
adjustment)
Cap.
length
Max.
bulb
temp.
Wholesaler
code
Orde
r
number
Type A19AAC Capillary thermostat, fixed differential
-35 to +10 2.5 1b set low 2 m 60 °C A19AAC-9102
-5 to +28 2 1b set low 2 m 60 °C A19AAC-9005
-5 to +28 2 1b set low 5 m 60 °C A19AAC-9124
1 to 60 2 1b set low 3 m 85 °C A19AAC-9127
40 to 120 3.5 1b set high 2 m 145 °C A19AAC-9009
35 to 150 4 1a set high 2 m 180 °C A19AAC-9107
90 to 290 5.5 1a set high 2 m 290 °C A19AAC-9108
Type A19ABC Capillary or immersion thermostat, adjustable differential
-35 to +40 2.8 to 8 1b set low 3.5 m 60 °C A19-A4
A19ABC-9037
-35 to +40 2.8 to 8 1b set low 6.5 m 60 °C A19-A5
A19ABC-9036
-35 to +10 2.8 to 11 1b set low 2 m 60 °C A19-A1
A19ABC-9103
-5 to +28 2 to 8 1b set low 2 m 60 °C A19-A2
A19ABC-9104
1 to 60 2 to 8 1b set low 5 m 85 °C
A19ABC-9117
1 to 60 2 to 8 1b set low 3 m 85 °C A19-A3
A19ABC-9116
10 to 95 3.5 to 13 1a set high 3.5 m 115 °C
A19ABC-9106
40 to 120 3.5 to 13 2 set high - 145 °C
A19ABC-9011
bulb well incl.
40 to 120 3.5 to 13 4h set high 2 m 145 °C
A19ABC-9012
bulb well incl.
Type A19ACC Capillary thermostat, lock-out low with manual reset
-35 to +10
6
M 1b set low 2 m 60 °C
A19ACC-9100
-35 to +10 N
6
M 1b set low 3.5 m 60 °C
A19ACC-9105
-35 to +10 N
6
M 1b set low 5 m 60 °C
A19ACC-9111
-35 to +10 N
6
M 1b set low 6.5 m 60 °C
A19-F
A19ACC-9116
-5 to +28
4
M 1b set low 2 m 60 °C
A19ACC-9101
-5 to +28
4
M 1b set low 5 m 60 °C
A19ACC-9103
-5 to +28
4
M 1b set low 3 m 60 °C
A19ACC-9107
Type A19ADC immersion thermostat, lock-out high with manual reset
40 to 120
7
O
2
set high - 145 °C
A19ADC-9200
bulb well incl.
Type A19AAF Capillary thermostat, close, fixed differential
0 to 10 1.5 1a set low 2 m 80 °C
A19AAF-9101
0 to 10 1.5 1a set low 2 m 80 °C A19-M P
A19AAF-9102
5 to 32 0.75 1b set high 2 m 60 °C
A19AAF-9103
M Indicates temperature increase above cut-out
point to make reset possible.
N Low limit stop factory set +2.5 °C may be
removed in the field.
O Indicates temperature decrease below cut-
out point to make reset possible.
P Milk-cooler thermostat.