Software House
IP-ACM Ethernet Door Module v2
Quick Start Guide
PART NUMBER: 8200-1466-01
VERSION: E0
SEPTEMBER 2019
Overview
The IP-ACM Ethernet Door Module v2 module provides connection and management of access control for two readers.
The maximum number of IP-ACM Ethernet Door Module v2 modules supported per iSTARUltra is 32, iSTARUltra SE
is 32, and iSTARUltra LT is 8 or 16, depending on the model.
The maximum number of readers can be accomplished as follows:
iSTARUltra or Ultra SE (in Ultra Mode): Up to 16 IP-ACMs with 2 readers per IP-ACM, 32 IP-ACMs with 1 reader
per IP-ACM, or any combination of these configurations.
iSTARUltra LT 16-reader board (0312-7188-02): Up to 8 IP-ACMs with 2 readers per IP-ACM, 16 IP-ACMs with
one reader per IP-ACM, or any combination of these configurations.
NOTE
For the 8-reader iSTAR Ultra LT board (0312-7188-01), you can have up to 4 IP-ACMs with 2 readers per IP-ACM, 8 IP-ACMs with
one reader per IP-ACM, or any combination of these configurations.
The 16-reader iSTAR Ultra LT board has not been evaluated by UL.
The IP-ACMEthernet Door Module v2 supports the following features:
12VDC or 24VDC local power or Power over Ethernet (PoE or PoE+)
Two RJ45 ports:
Port 1: Ethernet port, internally bound to MAC with the MAC address and used as the network connection port
for the board (10/100/1000)
Port 2: Switch port, not a secondary port, used for iSTARUltra LT connection (10/100, no PoE).
Caution: Do NOT plug this port into the same network as J1 or a loopback will occur.
Four supervised Inputs and two Outputs
Communication to readers through Wiegand or RS-485 ports
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls Tyco 8200-1466-01 and is the answer not in the manual?

Johnson Controls Tyco 8200-1466-01 Specifications

General IconGeneral
ManufacturerJohnson Controls
Model Number8200-1466-01
CategoryControl Unit
Operating Voltage24 VDC
Operating Temperature0°C to 49°C (32°F to 120°F)

Summary

Overview of IP-ACM Ethernet Door Module v2

Requirements and Specifications

Installation Requirements

Module installation must be performed by a certified installer and comply with UL standards.

Environmental Requirements

Grounding Requirements

Supervision Wiring

Configurable supervised input circuits using 1K EOL configuration for normally open or closed switches.

IP-ACM Ethernet Door Module v2 Power and Wiring

Installation and Enclosures

Plastic Enclosure

Dimensions and installation details for the plastic enclosure, not suitable for plenum use.

Metal Enclosure

Dimensions and installation details for the metal enclosure, approved for plenum use.

IP-ACM v2 Ethernet Door Module Features

Switches and Jumpers

Description of SW1 switch positions for normal and standalone operation modes.

Ports and Connectors

Factory Reset Procedure

Steps to perform a factory reset using SW2 rotary switch and SW3 reset button.

Specific Port Configurations

Details on RJ45 ports (J5), local power (P1), and Wiegand ports (P3/P4) configurations.

Wiring Diagrams

Wiegand Wiring

Diagrams and typical connections for Wiegand readers on the IP-ACM v2.

RS-485 Wiring

Wiring configurations for full duplex and half duplex RS-485 connections.

Inputs and Outputs

Output Relay Wet or Dry Configuration

Configuring output relays as Wet or Dry using jumpers for external power control.

Initial Configuration

Normal Operation Mode Configuration

Standalone Configuration Mode

802.1X Port-Based Authentication

802.1X Authentication Configuration

Offline Mode Configuration

Predefined Credentials and Access

Door Configuration in Offline Mode

Upgrading IP-ACM v2 Firmware