Functions and Control
DomesticAirConditioner
13
function of power on is optional. (In auto, heating, cooling, or defrosting status, press the button
to enter additional options
when cycle dispay to
will flash and then press quickly
press
and then press rapidly 10 times within 6 seconds, and the auto recovery function
of power on can be set on/off. If the buzzer rings 4 times, the the auto recovery function of power on is
available; If the buzzer rings 2 times, the the auto recovery function of power on is unavailable.)
If there is no EEPROM, the unit is taken off the ‘off’ function of the memory function of power down. But
the memory function of power down can also be set on/off, and the data is the default value of chip
5.2 Value of Thermistor
5.2.1 Indoor unit
Room sensor
R25 =2.ȍ3.5%
B25
/50 =4200K
Temp.( ) Max.(Kȍ) Normal(Kȍ 0LQ.ȍ Tolerance( )
-30 568.8372 501.0746 440.8435 -1.97 1.75
-29 530.9600 468.6491 413.1441 -1.95 1.74
-28 495.8488 438.5314 387.3645 -1.93 1.72
-27 463.2850 410.5433 363.3602 -1.91 1.71
-26 433.0683 384.5212 340.9980 -1.90 1.70
-25 405.0156 360.3153 320.1558 -1.88 1.69
-24 378.9588 337.7879 300.7211 -1.86 1.67
-23 354.7440 316.8126 282.5905 -1.84 1.66
-22 332.2300 297.2732 265.6686 -1.82 1.64
-21 311.2873 279.0627 249.8676 -1.80 1.63
-20 291.7969 262.0831 235.1067 -1.78 1.62
-19 273.6494 246.2437 221.3111 -1.76 1.60
-18 256.7445 231.4612 208.4122 -1.74 1.59
-17 240.9897 217.6590 196.3462 -1.72 1.57
-16 226.3000 204.7662 185.0545 -1.70 1.56
-15 212.5973 192.7176 174.4829 -1.68 1.54
-14 199.8093 181.4531 164.5813 -1.66 1.53
-13 187.8698 170.9169 155.3033 -1.64 1.51
-12 176.7176 161.0578 146.6059 -1.62 1.49
-11 166.2961 151.8284 138.4495 -1.60 1.48
-10 156.5532 143.1847 130.7973 -1.58 1.46
-9 147.4409 135.0863 123.6153 -1.56 1.44
-8 138.9148 127.4956 116.8717 -1.53 1.43
-7 130.9337 120.3778 110.5374 -1.51 1.41
YSCC24FSAADG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls York FREE MATCH EK Series and is the answer not in the manual?

Johnson Controls York FREE MATCH EK Series Specifications

General IconGeneral
BrandJohnson Controls
ModelYork FREE MATCH EK Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals