JOHNSON CONTROLS
8
FORM 150.62-NM6 (103)
PRODUCT IDENTIFICATION NUMBER (PIN)
EXAMPLES:
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
X X X X X X X X L X X X X X X X X X X X X X X X X X A X X X X X X X X X X X X X
S D T C A T S R L X P R S 2 5 C X 1 X X X X 3 D W S A R X B X X 4 B X X L X S D
OPTIONS MODEL NUMBER
: Aluminum
: Copper
: Black Fin
: Phenolic
: TEAO Fan
Motors
EVAP. FIELD CONDENSER FIELD CABINET FIELD
: Wire Condenser Headers Only (factory)
: Wire (Full Unit) Enc. Panels (factory)
: Wire (Full Unit) Enc. Panels (eld)
: Wire/Louvered Enc. Panels (factory)
: Wire/Louvered Enc. Panels (eld)
: Louvered (Cond. Only) Enc. Panels (factory)
: Louvered (Cond. Only) Enc. Panels (eld)
: Louvered (Full Unit) Enc. Panels (factory)
: Louvered (Full Unit) Enc. Panels (eld)
: Acoustic Sound Blanket
: Low Sound Fans
: 1" Deection
: Seismic
: Neoprene Pads
55
EXTENDED FIELD
X
B
C
D
E
F
G
H
: 1st Year Parts Only
: 1st Year Parts & Labor
: 2nd Year Parts Only
: 2nd Year Parts & Labor
: 5 Year Compressor Parts Only
: 5 Year Compressor Parts & Labor Only
: 5 Year Units Parts Only
: 5 Year Unit Parts & Labor
NOTES:
1. Q :DENOTES SPECIAL / S.Q.
2. # :DENOTES STANDARD
3. X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED
4. Agency Files (i.e. U.L. / E.T.L.; CE; ARI; ETC.) will contain info. based on the rst 14 characters only.
: Low Ambient Kit (factory)
: High Ambient Kit (factory)
: Both Low / High Ambient (factory)
: BAS/EMS Temp. Reset / Offset
: Spanish LCD & Keypad Display
: French LCD & Keypad Display
: German LCD & Keypad Display
: Discharge Pressure Transducers/
Readout Kit
: Suction Pressure Transducers /
Readout Kit
: Both Discharge & Suction Pressure
Transducers / Readout
: N. American Safety Code
(cU.L./cE.T.L.)
: No Listing (typically 50 HZ non-CE,
non-U.L.
: Remote Control Panel
: Sequence Control & Automatic
Lead Transfer
: 300 PSIG DWP Waterside
: Double Thick Insulation
: Weld Flange Kit
: Victaulic Flange Kit
: Flow Switch
: ASME Pressure Vessel &
Associated Codes
: Remote DX Cooler
: SP Supply TB
: MP Supply TB
: SP Supply TB
: SP NF Disconnect Switch
: SP Circuit Breaker w/ Lockable Handle
: Control Transformer (factory)
: Power Factor Capacitor
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
POWER FIELD CONTROLS FIELD COMPRESSOR / PIPING FIELD
X X L # #
X X H
S X A C
S D T S
B X S B
F E
G 1
T I
C R X
S X
B X
X
L
N
C
R
S
MP = Multiple Point
SP = Single-Point
NF = Non-Fused
TB = Terminal Block
Ser. = Service
Ind. Sys. Brkr. & L. Ext. Handles = Individual
System Breaker & Lockable
External Handle
38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
3 X X
D C 1
W B 2
V P 3
S X 4
A 5
6
R 7
8
B
L
1
S
N
: Leaving Supply Temp.
: Chicago Code Kit Req’d.
: Service Isolation Valves
: Both Chicago & Svc. Iso.
: Elec. Expansion Valve
: Hot Gas By-Pass req’d.
(1 circuit)
: X
: X
: X
: Crankcase Heater Std.