16
3.2 PRIMARY BATTERY
3.2.1 DESCRIPTION
The primary battery unit is a 7.2V / 2200mAh lithium battery. This unit
is specially designed for GMDSS emergency use to preserve a long shelf-
and operating-life.
This battery cannot be recharged.
Type no. of battery: 80060
Colour: Orange
3.2.2 WHEN TO CHANGE BATTERY
Replace the lithium battery before expiry date. The lithium battery pack has a
shelf life of 5 years. If Tron TR20 is indicating low voltage during normal use,
the lithium battery will have to be replaced. Please refer to section 3.1 for battery
replacement.
To prevent the possibility of being in an emergency situation with a Tron TR20
equipped with a used battery, we strongly recommend storing an extra battery,
in lifeboats and rafts. Store this battery without breaking the sealing.
3.2.3 SPECIAL CARE
The primary battery is of a high-energy lithium type, and some precautions must
be taken. Do not heat above 70°C, recharge, crush, disassemble or incinerate. This
may result in fire, explosion and severe burn hazard.
Do not throw used batteries overboard, but return them to your local dealer.