8.4 REPLACEMENT OF MAJOR PARTS
ņ56
8
yyyy
yyyy
Close the upper housing while pulling the center of the stay.

If any hexagonal bolt is not tightened enough or is loosened, the waterproof performance
may be deteriorated. Be sure to tighten all bolts with specified torque (120 to 150kgf·cm).
After the work, turn "ON" the safety switch.
When closing the housing, be careful that the cables are not caught.
When closing the upper housing, always pull the center of the stay. Otherwise the stay may be broken.

This completes the motor replacement procedure.
Stay