6.2  MAINTENANCE ON EACH UNIT 
 
 
 
 
CAUTION 
 
 
Do not put watches, clocks, or magnetic cards 
close to the modulator unit since this unit holds 
magnetrons having strong magnetic force.   
Failure or data destruction of the above devices 
 
 
After finishing the maintenance work, turn “ON” the safety switch of scanner unit. 
 
Precautions in Mounting the Cover 
 
When the cover is removed for regular checkup and replacement of parts and refitted after such work, the 
procedures of fastening bolts shall be taken with the following precautions: 
 
(a)  The proper fastening torque of the fitting bolts (M8) is 1176 to 1470 N•cm (120 to 150kgf•cm) (which 
makes the inside water-tight and protects the packing against permanent compressive strain). 
  The packing starts being produced from a torque of approximately 1470N•cm (150kgf•cm) on the cover. 
  Do not fasten the bolts with a torque exceeding the specified value.  Otherwise, the screws may be 
broken. 
(b)  Use an offset wrench of 11 mm × 13 mm or a double-ended wrench of 13 mm × 17 mm (not longer than 
200 mm). 
(c)  Screw all the bolts by hand first to prevent them playing, then fasten them evenly in order not to cause 
one-sided fastening. (Fasten the bolts with 25% of the required torque at the first step.) 
 
  *: Fasten the bolts in the diagonal order. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Top View of NKE-387 
Figure 6.1 Bolt Tightening Procedure of NKE-387 Cover 
 
 